FCV12-3R By Pass Flow Control With Relief
OPERATION
The valve regulates flow from port `P` to port `R`and by-passes the excess to port `T`. The regulated flow from port `R`remains virtually constant regardless of load variations, and can be adjusted from zero to 70 litres/min. maximum by turning the adjustmentscrew counter-clockwise. The maximum pressure at port `R` is set by adjusting the pressure relief setting. The blocking of port `R` is not recommended as it will cause pressure build-up and overheating in the hydraulic system.
FEATURES
- Compact.
- Steel housing.
- Tamper resistant pressure adjustment.
- Stainless steel flow adjuster assembly.
- All cartridges 100% factory tested.
- Desired settings may be locked.
- Captive flow adjuster cannot be backed out of valve.Optional handwheel flow adjuster (P/N HW17).
SPECIFICATIONS
- OPERATING PRESSURE: 210 bar (3000 p.s.I.) max.
- MEDIA: general purpose hydraulic fluids @ -40º c to +120º c.
- FLOW: inlet – max. 80 l./min., auxiliary – max. 70 l./min.
- WEIGHT: 1.9 Kg.
- MATERIALS: All parts are steel, except seals. Standard seals are Buna N with teflon backups. Viton seals are available on special order.

IMPORTANT PRECAUTIONS
All ports are B.S.P. parallel, and appropriate fittings must be used. Tapered fittings are not acceptable. Failure to correctly install or set these valves may result in damage to property, personal injury or death.
NOTES
VALVES ARE NOT PRESET, AND MUST BE ADJUSTED TO SUIT EACH APPLICATION PRIOR TO USE, USING APPROPRIATE TESTING EQUIPMENT.ALL DETAILS ARE APPROXIMATE, AND SUBJECT TO CHANGE WITHOUT NOTICE.


Prime Motion & Control have extensive design and manufacturing capabilities.